Contrast-enhanced harmonic endoscopic ultrasonography of solid pancreatic lesions


1 Department of Gastroenterology and Hepatology, Changi General Hospital, Singapore
2 Department of Gastroenterology, Asan Medical Centre, University of Ulsan College of Medicine, Seoul, South Korea
3 Department of Endoscopy, Jikei University School of Medicine, Tokyo, Japan

Date of Submission18-Jul-2013
Date of Acceptance04-Sep-2013
Date of Web Publication6-Sep-2013

Correspondence Address:
Tiing Leong Ang
Department of Gastroenterology and Hepatology, Changi General Hospital
Singapore
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/2303-9027.117658

Rights and Permissions
  Abstract 

Endoscopic ultrasonography is the best modality for pancreatic lesion evaluation as its superior spatial resolution allows small lesions to be identified and fine needle aspiration (FNA) cytology performed under ultrasound-guidance. Despite this, differentiating benign from malignant lesions remains a challenge as conventional ultrasound imaging is unable to differentiate lesions accurately and tissue yield is poorly diagnostic or limited in patients with the chronic inflammation. Contrast-harmonic technology uses a wide-band transducer capable of inducing sufficient acoustic energy to create harmonic microbubble oscillations of the newer second-generation ultrasound contrast agents (UCAs). These microbubbles are more stable, remaining within the intravascular component longer and emit significantly more harmonic content than surrounding tissue, thus allowing pancreatic parenchymal differentiation and microvascular architecture visualization. The use of UCAs is generally safe, but should be especially avoided in patients with unstable ischemic heart disease. During CH endosonography, pancreatic adenocarcinoma is commonly seen as an inhomogenous hypoenhancing lesion, focal pancreatitis as a hypo- or iso-enhancing lesion and neuroendocrine tumor as a hyperenhancing lesion. The presence of hyperenhancement is a strong predictor of non-adenocarcinoma etiology. Furthermore, in patients with the chronic pancreatitis or biliary stents that may obscure pancreatic inspection, the addition of contrast-harmonic endosonography to guide FNA cytology improves its diagnostic yield and accuracy. Quantitative analysis of perfusion through the time intensity curve is promising as an objective and accurate method to differentiate pancreatic lesions. Furthermore, studies are required to fully determine the role of contrast harmonic endosonography in the differential diagnosis of solid pancreatic lesions.

Keywords: Contrast-harmonic; pancreas; endoscopic ultrasonography


How to cite this article:
Kwek BE, Ang TL, Seo DW, Imazu H. Contrast-enhanced harmonic endoscopic ultrasonography of solid pancreatic lesions. Endosc Ultrasound 2013;2:142-7

How to cite this URL:
Kwek BE, Ang TL, Seo DW, Imazu H. Contrast-enhanced harmonic endoscopic ultrasonography of solid pancreatic lesions. Endosc Ultrasound [serial online] 2013 [cited 2019 Dec 12];2:142-7. Available from: http://www.eusjournal.com/text.asp?2013/2/3/142/117658


  Introduction Top


Ever since endoscopic ultrasonography (EUS) was first introduced in 1980, [1],[2],[3] its superior spatial resolution cemented its popularity as an important tool to localize and characterize pancreatic lesions. [4],[5],[6] Distinguishing malignant lesions from benign ones allows appropriate and early curative surgery for resectable adenocarcinoma and avoids surgery for non-neoplastic lesions such as inflammatory masses associated with chronic pancreatitis. However, despite the advances in technology of multi-detector row computed tomography (CT), magnetic resonance imaging (MRI) and conventional EUS, none of these modalities is able to differentiate the types of solid pancreatic lesions reliably. [7],[8],[9] Also, the addition of EUS-guided fine-needle aspiration (FNA) cytology did not improve diagnostic accuracy reliably as the negative predictive value for diagnosing cancer remains low at about 70%. [10]

Contrast-enhanced (CE) EUS evolved from simple power Doppler EUS evaluation with contrast injection to a wideband dedicated transducer, which is now widely known as contrast-enhanced harmonic-EUS (CH-EUS). [11] Although power Doppler sonography is able to detect vascular flow patterns, it has low sensitivity for detecting microvessels and is limited by multiple tissue artifacts such as blooming (overpainting) and tissue motion (flash). [10],[12] Harmonic technology allows detection of microbubbles within slow-flow microvessels without Doppler-related artifacts. CH-EUS studies have described specific enhancement patterns for pancreatic lesions. This technology was made possible with the combined advances of having a EUS transducer strong enough to produce sufficient acoustic power and the availability of contrast agents that remain in the microcirculation while producing harmonic signals at lower power requirements.

This review describes the technology of CH-EUS and its clinical application in patients with solid pancreatic lesions.


  Ultrasound Contrast Agents (UCAs) Top


In comparison with contrast agents for CT or MRI, UCAs remain within the intravascular space and do not diffuse into the interstitial space. [13] The second generation UCAs contain inert gases with lower water-solubility and diffusion coefficient than the first generation agents and thus improved stability and contrast duration. [14] These high molecular weight gases include perfluoropentane and sulfurhexafluoride, whereas the microbubble shells consist of phospholipids, polymers, surfactant or albumin.

Commonly used agents include sonovue (Bracco Imaging, Milan, Italy), sonazoid (Daiichi-Sankyo, Tokyo, Japan), definity (Lantheus Medical Imaging, Mass, USA) and imagent (IMCOR Pharmaceutical Co.). Among these, the most experience is with sonovue. It is microbubbles contain sulfurhexafluoride, an inert and poorly soluble gas. It is provided as a lyophilisate powder in a phospoholipid-stabilized sulfurhexafluoride microbubble, sealed within a glass vial. Reconstitution with the addition of saline and gentle shaking lead to a white milky solution. The recommended dosage is 2-2.4 ml, which is injected intravenously into a large peripheral vein, where it remains within the intravascular compartment till the gas dissolves and is expired in the lungs. [15] Sonazoid has microbubbles of perfluorobutane with a lipid membrane encapsulation. Definity consists of perfluopenthane within a phospholipid shell and is commonly used in contrast echocardiography. [16] UCAs differ in their signal intensity and duration following infusion. It has been described that sonovue's intensity declines within 60 s, [11] whereas sonazoid allows parenchymal perfusion observation for at least 90 s. [17] However, in clinical practice, the duration of contrast observation may vary as contrast destruction depends not only on the type of contrast used, but also on the target lesion's distance from the transducer as well as imaging parameters such as the mechanical index (MI), pulse repetition frequency and pulse length.


  Harmonic Technology Top


The basic principle of UCAs is that while gases are compressible, tissue is almost incompressible. [14] During an ultrasound wave, volumetric oscillation of microbubbles occurs with compression during pressure peaks and expansion during pressure nadirs. Besides the type of gas and property of the bubble shell, the acoustic power of the ultrasound influences the vibration of the microbubbles. To quantify the insonation energy from the transmitted ultrasound wave transducer, the MI is calculated from the maximum negative sound pressure divided by the square root of the sound frequency. It reflects the probability of cavitation resulting from an acoustic beam. Varying acoustic powers produces varying effects. Very low acoustic power (MI <0.1) produces symmetrical oscillations and the scattered signal frequency is similar to that of the emitted sound wave. At low acoustic powers (MI: 0.1-0.6), a non-linear response occurs due to the microbubbles resisting compression more strongly than expansion. This leads to multiples of insonating frequency being present within the returning signals. These higher frequency components are known as harmonics. Because microbubbles produce harmonic content that are significantly higher than tissue, CH imaging highlights areas with higher harmonic content of microbubbles and filter the lower signals that arise from tissue. [18] This strong acoustic signal is detected and visualized as an opacification on an ultrasound image. When the acoustic power is further increased (MI >0.6), disruption of the microbubble shell occurs and transient resonance of free gas bubbles result in a very strong echo signal.

There are various imaging modalities to detect UCA and the chosen technique is based on the contrast agent used and on the machine platform. Contrast-specific imaging procedures include single-pulse and multi-pulse procedures, of which pulse-inversion mode is the simplest modality.

In 2005, Dietrich et al., first reported the use of CH-EUS in six patients. [19] They used sonovue injection with an adapted dynamic contrast harmonic wide-band pulse-inversion software with low MI, demonstrating that arterial, portal venous and parenchymal contrast-enhancement were possible. Since then, numerous studies showed the usefulness of CH-EUS in differentiating benign from malignant lesions. Kitano et al., in particular, described the optimal settings and clinical role of CH-EUS in evaluating the parenchymal perfusion and microvessel architecture in pancreaticobiliary and other gastrointestinal (GI) diseases. [11] In his study, sonovue infusion with intermittent imaging at MI of 0.4 and interval delay-scanning time of more than 2 s produced homogenous enhancement of the pancreas. With MI of 0.4 and real-time continuous imaging, microvascular architecture could be visualized.


  How to Perform CH Endosonography Top


At our center, we use the ALOKA ProSound SSD α-10 image processor (ALOKA, Tokyo, Japan) with a dedicated echoendoscope (GF-UE160-AL5, Olympus Medical Systems, Tokyo, Japan). With the patient in the left lateral decubitus position and sedation with intravenous midazolam and fentanyl, the echoendoscope is inserted into the upper GI tract and the whole pancreas is surveyed by conventional B mode EUS. Subsequently, we switch to the extended pure harmonic detection (ExPHD) imaging mode. ExPHD for tissue harmonic echo (THE) and for contrast harmonic echo (CHE) are used. THE mode is better for imaging the entire anatomical structures of the pancreaticobiliary system, whereas CHE is more specific in accentuating the vascular pattern following contrast injection. At our center in Singapore, the UCA definity and sonovue are available. In Japan, sonazoid and sonovue are utilized whereas in Korea, sonovue is used. Definity is used at a dose of 10 ul/kg body weight, injected into an 18-gauge intravenous cannula situated in the antecubital fossa, followed by 5 ml of saline flush. The MI is set at 0.3 as it provided the optimal balance between contrast enhancement and effect duration of contrast. [20] At a frequency of 5 MHz, we used intermittent mode for parenchymal evaluation and continuous mode for microvascular assessment. For Sonovue, we inject 2.4 ml of the reconstituted solution, followed by 5 ml of saline. MI is set at 0.4.


  CH-EUS Features of Solid Pancreatic Lesions Top


Adenocarcinoma

Ductal adenocarcinoma [Figure 1]A-C is characteristically poorly vascularized. On CH-EUS, the presence of irregular network-like vessels in a relatively hypovascular lesion were highly suggestive of pancreatic adenocarcinoma. [11],[20] In 49 of 51 patients with pancreatic adenocarcinoma, Fusaroli et al., reported presence of inhomogeneous hypoenhancement with fast washout. However, rarely, some pancreatic adenocarcinoma may appear iso- or hyperenhancing. [21]
Figure 1. Pancreatic adenocarcinoma: Hypoechoic pancreatic mass. (A) On conventional endoscopic ultrasonography (EUS); (B) on contrast-enhanced harmonic (CH)-EUS (pre-contrast); (C) on CH-EUS (post-contrast)

Click here to view


Focal pancreatitis/autoimmune pancreatitis

The differentiation of focal pancreatitis from pancreatic adenocarcinoma is challenging as cytological evaluation in the setting of chronic pancreatitis is limited by inflammatory infiltrates that could obscure or simulate malignancy. [22] Fusaroli et al., [21] reported hypoenhancement in nine patients and isoenhancement in four patients with focal pancreatitis. In this regard, hypoenhancement alone has poor specificity and may not reliably diagnose malignancy.

To improve on its accuracy to differentiate autoimmune pancreatitis [Figure 2]A-C from pancreatic adenocarcinoma, Imazu et al., used CH-EUS with quantitative perfusion analysis via a "time intensity curve" software. [23] Using maximum intensity gain (MIG), which was the difference between peak intensity and base intensity before contrast injection, they showed that a MIG cut-off value of 12.5 dB had excellent sensitivity and specificity to differentiate autoimmune pancreatitis from pancreatic carcinoma. Though promising, further studies are required to determine its utility for differentiating various types of pancreatic lesions.
Figure 2. Focal autoimmune pancreatitis. (A) Hypoechoic pancreatic mass on conventional endoscopic ultrasonography; (B) hypoechoic pancreatic mass on contrast-enhanced harmonic endoscopic ultrasonography (CH-EUS) (pre-contrast); (C) iso-enhancing pancreatic mass on CH-EUS (post-contrast)

Click here to view


Neuroendocrine tumor

Although, it appears hypoechoic on conventional EUS, neuroendocrine tumors [Figure 3]A-C are classically homogenously enhancing on CH-EUS. [11] This is consistent with previous reports on CE transabdominal US that described hypervascular enhancement in 80% to 87% of endocrine tumors. [24],[25] Although hyperenhancement is not specific for neuroendocrine tumor, this feature is a strong predictor for histology other than adenocarcinoma (94% positive predictive value), with neuroendocrine tumor being the most common (56%). [21]
Figure 3. Neuroendocrine tumor. A: Hypoechoic pancreatic mass on conventional endoscopic ultrasonography; B: hypoechoic pancreatic mass on contrast-enhanced harmonic endoscopic ultrasonography (CH)-EUS (pre-contrast); C: homogenously-enhancing pancreatic mass on CH-EUS (post-contrast)

Click here to view



  Safety and Complications Top


UCAs approved for clinical use are generally well-tolerated and safe. The risks associated with UCAs are related to biologic effects from ultrasound-induced cavitation, toxicity, embolic risk and anaphylactic risk. Implosion of microbubbles or the cavitation phenomenon occurs due to the low-pressure and high-pressure wave phases of the ultrasound. While the gas bubble is formed during the low-pressure phase, this gas bubble collapses during the high-pressure phase, leading to a large amount of energy being transmitted causing significant changes in pressure and temperature within the close vicinity. This can result in formation of free radicals, electromagnetic radiation and lysis of adjacent cells. Although hemolysis and platelet aggregation effects have been seen in animal studies, these side-effects have not been seen in clinical practice. [26] The toxicity and embolic potential of UCAs were also deemed to be of no clinical significance by the European committee for medical ultrasound safety. [14] However, as the component shell and excipients of the UCAs are derived from macromolecular substances, there is a risk of allergic reactions. These are mostly mild such as transient rash or sensation of heat but rarely, anaphylactic hypersensitivity reactions may occur. In addition, UCAs should not be used in patients with unstable ischemic heart disease. [27] The European Medicine Agency has limited the use of the agent sulfurhexafluoride in patients with cardiac disease after a number of serious allergic reactions with cardiovascular complications and deaths were reported. Other listed contraindications include the presence of right-to-left shunts, severe pulmonary hypertension, uncontrolled systemic hypertension and adult respiratory distress syndrome.


  Performance Characteristics Top


Prior to CH-EUS studies, Sakamoto et al., compared the sensitivity of non-harmonic CE EUS, power-Doppler EUS and CE multidetector computed tomography (MDCT) for differentiating pancreatic tumors 2 cm or smaller. Despite its limitation in depicting fine vessels and parenchymal perfusion, CE-EUS had the best sensitivity for differentiating ductal adenocarcinoma from other tumors; 83.3%, 11.0% and 50.0%, respectively. [28]

The value of CH-EUS was demonstrated by Kitano et al., in a study of 277 patients with solid pancreatic lesions. [17] In his study, besides diagnosing ductal adenocarcinoma with high sensitivity and specificity (95.1% and 89.0%, respectively) based on a hypoenhancement pattern on CH-EUS, there was also an excellent inter-observer agreement with a kappa coefficient of 0.94. In addition, neuroendocrine tumors were diagnosed by the presence of hypervascular enhancement, with sensitivity and specificity of 78.9% and 98.7%, respectively. [Table 1] summarizes the performance characteristics of recent studies using CH-EUS in patients with solid pancreatic lesions.
Table 1. Performance characteristics of CH-EUS in patients with pancreatic lesions


Click here to view


Similarly, a study by Napolean et al., reported sensitivity, specificity, negative predictive value, positive predictive value and accuracy of hypointensity for diagnosing pancreatic adenocarcinoma of 89%, 88%, 88%, 89% and 88.5%. [10] The value of CH-EUS was highlighted when compared with EUS-guided EUS-FNA, which had corresponding performance characteristics of 72%, 100%, 77%, 100% and 86%. Although the study of Kitano et al. [17] did not show CH-EUS to be more superior to EUS-FNA, five patients with false-negative EUS-FNA findings had hypo-enhancement suggestive of adenocarcinoma on CH-EUS. By combining CH-EUS with EUS-FNA, the sensitivity for cancer diagnosis was increased from 92.2% to 100%.

In comparison with CH-EUS, MDCT did not differ significantly in its ability to diagnose ductal adenocarcinoma; 95.1% vs 91.7%, respectively. [17] However, due to EUS's better spatial resolution, it was not surprising that CH-EUS was significantly more sensitive than MDCT in detecting small cancers <2 cm; 91.2% vs 70.6%, respectively.


  Future Directions Top


In seven patients where presence of biliary stent or diffuse chronic pancreatitis led to poor pancreatic visualization on conventional EUS, CH-EUS was able to detect small hypoenhancing lesions. This guided FNA and pancreatic adenocarcinoma was subsequently diagnosed. [21] The value of CH-EUS as a guide for not only detection, but improving histological yield will require larger studies for further confirmation.

Imazu et al., described an improvement in T-staging for patients with pancreaticobiliary malignancy when CH-EUS was used instead of harmonic EUS alone; 92.4% vs 69.2%, respectively. [29] Larger studies with multimodality comparison including that with current high resolution CE MDCT may further distinguish its role in tumor staging.

A limitation of CH-EUS is the subjectivity of an operator's impression of lesion enhancement, which is dependent on one's experience. To overcome this limitation, quantitative methods of recording perfusion based on contrast intensity was created and studied by various authors. [23],[30] This objective technique may further improve the accuracy of CH-EUS to differentiate various pancreatic etiologies.

Another promising feature of contrast-harmonic technology is its potential to selectively deliver therapy and reduce undesired side-effects in other non-targeted organs using contrast microbubbles as drug/gene carriers. This concept relies on the high acoustic pressure ultrasound-induced microbubble destruction to release the carrier drug or plasmid deoxyribonucleic acid at the targeted site. [31]


  Conclusion Top


CH-EUS allows detailed parenchymal and microvascular evaluation of focal solid pancreatic lesions. It overcomes the limitation of artifacts associated with contrast-enhancement with Doppler EUS. The presence of hyperenhancement has a strong predictive value of non-adenocarcinoma diagnosis. Objective methods to quantify perfusion analyses may improve its diagnostic accuracy in the differential diagnosis of pancreatic lesions.

 
  References Top

1.DiMagno EP, Buxton JL, Regan PT, et al. Ultrasonic endoscope. Lancet 1980; 1: 629-31.  Back to cited text no. 1
[PUBMED]    
2.Hisanaga K, Hisanaga A, Nagata K, et al. High speed rotating scanner for transgastric sonography. AJR Am J Roentgenol 1980; 135: 627-9.  Back to cited text no. 2
[PUBMED]    
3.Strohm WD, Phillip J, Hagenmüller F, et al. Ultrasonic tomography by means of an ultrasonic fiberendoscope. Endoscopy 1980; 12: 241-4.  Back to cited text no. 3
    
4.Rösch T, Lorenz R, Braig C, et al. Endoscopic ultrasound in pancreatic tumor diagnosis. Gastrointest Endosc 1991; 37: 347-52.  Back to cited text no. 4
    
5.DeWitt J, Devereaux B, Chriswell M, et al. Comparison of endoscopic ultrasonography and multidetector computed tomography for detecting and staging pancreatic cancer. Ann Intern Med 2004; 141: 753-63.  Back to cited text no. 5
[PUBMED]    
6.Rösch T, Lightdale CJ, Botet JF, et al. Localization of pancreatic endocrine tumors by endoscopic ultrasonography. N Engl J Med 1992; 326: 1721-6.  Back to cited text no. 6
    
7.Boll DT, Merkle EM. Differentiating a chronic hyperplastic mass from pancreatic cancer: A challenge remaining in multidetector CT of the pancreas. Eur Radiol 2003; 13 Suppl 5: M42-9.  Back to cited text no. 7
[PUBMED]    
8.Schima W. MRI of the pancreas: Tumours and tumour-simulating processes. Cancer Imaging 2006; 6: 199-203.  Back to cited text no. 8
[PUBMED]    
9.Brand B, Pfaff T, Binmoeller KF, et al. Endoscopic ultrasound for differential diagnosis of focal pancreatic lesions, confirmed by surgery. Scand J Gastroenterol 2000; 35: 1221-8.  Back to cited text no. 9
[PUBMED]    
10.Napoleon B, Alvarez-Sanchez MV, Gincoul R, et al. Contrast-enhanced harmonic endoscopic ultrasound in solid lesions of the pancreas: Results of a pilot study. Endoscopy 2010; 42: 564-70.  Back to cited text no. 10
[PUBMED]    
11.Kitano M, Sakamoto H, Matsui U, et al. A novel perfusion imaging technique of the pancreas: Contrast-enhanced harmonic EUS (with video). Gastrointest Endosc 2008; 67: 141-50.  Back to cited text no. 11
[PUBMED]    
12.Sãftoiu A, Dietrich CF, Vilmann P. Contrast-enhanced harmonic endoscopic ultrasound. Endoscopy 2012; 44: 612-7.  Back to cited text no. 12
    
13.Claudon M, Cosgrove D, Albrecht T, et al. Guidelines and good clinical practice recommendations for contrast enhanced ultrasound (CEUS)-update 2008. Ultraschall Med 2008; 29: 28-44.  Back to cited text no. 13
[PUBMED]    
14.Sanchez MV, Varadarajulu S, Napoleon B. EUS contrast agents: What is available, how do they work, and are they effective? Gastrointest Endosc 2009; 69: S71-7.  Back to cited text no. 14
[PUBMED]    
15.Bokor D. Diagnostic efficacy of SonoVue. Am J Cardiol 2000; 86 Suppl: 19G-24.  Back to cited text no. 15
    
16.Wei K, Mulvagh SL, Carson L, et al. The safety of deFinity and optison for ultrasound image enhancement: A retrospective analysis of 78,383 administered contrast doses. J Am Soc Echocardiogr 2008; 21: 1202-6.  Back to cited text no. 16
[PUBMED]    
17.Kitano M, Kudo M, Yamao K, et al. Characterization of small solid tumors in the pancreas: The value of contrast-enhanced harmonic endoscopic ultrasonography. Am J Gastroenterol 2012; 107: 303-10.  Back to cited text no. 17
[PUBMED]    
18.Kudo M. Contrast harmonic imaging in the diagnosis and treatment of hepatic tumors. In: Contrast Imaging. Ch. 11. Tokyo: Springer; 2003. p. 69.  Back to cited text no. 18
    
19.Dietrich CF, Ignee A, Frey H. Contrast-enhanced endoscopic ultrasound with low mechanical index: A new technique. Z Gastroenterol 2005; 43: 1219-23.  Back to cited text no. 19
[PUBMED]    
20.Ang TL, Teo EK, Ang D, et al. A pilot study of contrast harmonic endosonography using DEFINITY™ in the evaluation of suspected pancreatic and peri-ampullary malignancies. J Interv Gastroenterol 2011; 1: 160-5.  Back to cited text no. 20
[PUBMED]    
21.Fusaroli P, Spada A, Mancino MG, et al. Contrast harmonic echo-endoscopic ultrasound improves accuracy in diagnosis of solid pancreatic masses. Clin Gastroenterol Hepatol 2010; 8: 629-341.  Back to cited text no. 21
[PUBMED]    
22.Erickson RA, Sayage-Rabie L, Beissner RS. Factors predicting the number of EUS-guided fine-needle passes for diagnosis of pancreatic malignancies. Gastrointest Endosc 2000; 51: 184-90.  Back to cited text no. 22
[PUBMED]    
23.Imazu H, Kanazawa K, Mori N, et al. Novel quantitative perfusion analysis with contrast-enhanced harmonic EUS for differentiation of autoimmune pancreatitis from pancreatic carcinoma. Scand J Gastroenterol 2012; 47: 853-60.  Back to cited text no. 23
[PUBMED]    
24.Kitano M, Kudo M, Maekawa K, et al. Dynamic imaging of pancreatic diseases by contrast enhanced coded phase inversion harmonic ultrasonography. Gut 2004; 53: 854-9.  Back to cited text no. 24
[PUBMED]    
25.Yang W, Chen MH, Yan K, et al. Differential diagnosis of non-functional islet cell tumor and pancreatic carcinoma with sonography. Eur J Radiol 2007; 62: 342-51.  Back to cited text no. 25
[PUBMED]    
26.Thomsen HS. Contrast Media: Safety issues and Esur guidelines. In: Thomsen HS, Webb JAW (eds). Safety of Ultrasound Contrast Agents. Ch. 19. Germany: Springer; 2009. p. 131-5.  Back to cited text no. 26
    
27.Raisinghani A, DeMaria AN. Physical principles of microbubble ultrasound contrast agents. Am J Cardiol 2002; 90: 3J-7.  Back to cited text no. 27
[PUBMED]    
28.Sakamoto H, Kitano M, Suetomi Y, et al. Utility of contrast-enhanced endoscopic ultrasonography for diagnosis of small pancreatic carcinomas. Ultrasound Med Biol 2008; 34: 525-32.  Back to cited text no. 28
[PUBMED]    
29.Imazu H, Uchiyama Y, Matsunaga K, et al. Contrast-enhanced harmonic EUS with novel ultrasonographic contrast (Sonazoid) in the preoperative T-staging for pancreaticobiliary malignancies. Scand J Gastroenterol 2010; 45: 732-8.  Back to cited text no. 29
[PUBMED]    
30.Kersting S, Konopke R, Kersting F, et al. Quantitative perfusion analysis of transabdominal contrast-enhanced ultrasonography of pancreatic masses and carcinomas. Gastroenterology 2009; 137: 1903-11.  Back to cited text no. 30
[PUBMED]    
31.Hernot S, Klibanov AL. Microbubbles in ultrasound-triggered drug and gene delivery. Adv Drug Deliv Rev 2008; 60: 1153-66.  Back to cited text no. 31
    


    Figures

  [Figure 1], [Figure 2], [Figure 3]
 
 
    Tables

  [Table 1]


This article has been cited by
1 Extramedullary Plasmacytoma of the Pancreas Complicated with Left-Sided Portal Hypertension—a Case Report and Literature Review
Ján Csomor,Bohuš Bunganic,Dominika Dvoráková,Petr Hríbek,Klára Kmochová,Vít Campr,Inna Tucková,Cyril Šálek,Petr Urbánek,Miroslav Zavoral
Journal of Gastrointestinal Cancer. 2018;
[Pubmed] | [DOI]
2 The clinical impact of ultrasound contrast agents in EUS: a systematic review according to the levels of evidence
Pietro Fusaroli,Bertrand Napoleon,Rodica Gincul,Christine Lefort,Laurent Palazzo,Maxime Palazzo,Masayuki Kitano,Kosuke Minaga,Giancarlo Caletti,Andrea Lisotti
Gastrointestinal Endoscopy. 2016;
[Pubmed] | [DOI]
3 Endoscopic Ultrasound in the Diagnosis and Staging of Pancreatic Cancer
Bruno Gonçalves,Joăo Bruno Soares,Pedro Bastos
GE Portuguese Journal of Gastroenterology. 2015; 22(4): 161
[Pubmed] | [DOI]
4 Endosonographic Workup and Preoperative Biliary Drainage for Pancreatic Cancer
Harkirat Singh,Ali A. Siddiqui
Seminars in Oncology. 2015; 42(1): 59
[Pubmed] | [DOI]



 

Top
 
 
  Search
 
Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
Access Statistics
Email Alert *
Add to My List *
* Registration required (free)

 
  In this article
   Abstract
  Introduction
   Ultrasound Contr...
  Harmonic Technology
   How to Perform C...
   CH-EUS Features ...
   Safety and Compl...
   Performance Char...
  Future Directions
  Conclusion
   References
   Article Figures
   Article Tables

 Article Access Statistics
    Viewed1720    
    Printed54    
    Emailed0    
    PDF Downloaded434    
    Comments [Add]    
    Cited by others 4    

Recommend this journal


[TAG2]
[TAG3]
[TAG4]