• Users Online:1238
  • Home
  • Print this page
  • Email this page
Home About us Editorial board Search Ahead of print Current issue Archives Submit article Instructions Subscribe Contacts Login 
ORIGINAL ARTICLE
Year : 2016  |  Volume : 5  |  Issue : 5  |  Page : 315-319

Endoscopic ultrasonography-guided placement of a transhepatic portal vein stent in a live porcine model


1 Department of Internal Medicine, Hallym University Chuncheon Sacred Heart Hospital, Hallym University College of Medicine, Chuncheon, Korea
2 Department of Internal Medicine, Division of Gastroenterology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
3 Department of Gastroenterology, Asan Institute for Life Sciences, Asan Medical Center, Seoul, Korea

Correspondence Address:
Dong Wan Seo
Department of Internal Medicine, Division of Gastroenterology, Asan Medical Center, University of Ulsan College of Medicine, 88 Olympic-ro 43-gil, Songpa-gu, Seoul 138-736
Korea
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/2303-9027.191611

Rights and Permissions

Background and Objectives: Percutaneous portal vein (PV) stent placement is used to manage PV occlusion or stenosis caused by malignancy. The use of endoscopic ultrasonography (EUS) has expanded to include vascular interventions. The aim of this study was to examine the technical feasibility and safety of EUS-guided transhepatic PV stent placement in a live porcine model. Materials and Methods: EUS-guided transhepatic PV stent placement was performed in six male miniature pigs under general anesthesia using forward-viewing echoendoscope. Under EUS guidance, the left intrahepatic PV was punctured with a 19-gauge fine-needle aspiration (FNA) needle and a 0.025 inch guidewire inserted through the needle and into the main PV. The FNA needle was then withdrawn and a needle-knife inserted to dilate the tract. Under EUS and fluoroscopic guidance, a noncovered metal stent was inserted over the guidewire and released into the main PV. Results: A PV stent was placed successfully in all six pigs with no technical problems or complications. The patency of the stent in the main PV was confirmed using color Doppler EUS and transhepatic portal venography. Necropsy of the first three animals revealed no evidence of bleeding and damage to intra-abdominal organs or vessels. No complications occurred in the remaining three animals during the 8 weeks observation period. Conclusions: EUS-guided transhepatic PV stent placement can be both technically feasible and safe in a live animal model.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed1037    
    Printed14    
    Emailed0    
    PDF Downloaded190    
    Comments [Add]    
    Cited by others 1    

Recommend this journal