• Users Online:590
  • Home
  • Print this page
  • Email this page
Home About us Editorial board Search Ahead of print Current issue Archives Submit article Instructions Subscribe Contacts Login 
ABSTRACT
Year : 2017  |  Volume : 6  |  Issue : 7  |  Page : 4

Endoscopic ultrasonography-guided intrahepatic portal vein embolization in an animal model


Asan Medical Center, Seoul, Korea

Correspondence Address:
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/2303-9027.212257

Rights and Permissions

Background and Objectives: Preoperative portal vein embolization (PVE) by percutaneous transhepatic approach has been performed in candidates of major liver resection including right hepatectomy and extended right hepatectomy. This procedure can increase volume of remnant liver and prevent postoperative hepatic failure. The aim of this animal study is to evaluate the technical feasibility and safety of endoscopic ultrasonography (EUS)-guided intrahepatic PVE. Methods: EUS-guided intrahepatic PVE with coil and histoacryl was performed in seven pigs under general anesthesia using linear array echoendoscope. The intrahepatic portal vein (PV) was punctured with a 19-gauge FNA needle, and an embolization coil was inserted into the selected intrahepatic PV. Then, histoacryl was injected through the same FNA needle. The blood flow change in the selected intrahepatic PV was evaluated by color Doppler EUS. After 1-week observation period, necropsy was performed. Results: Embolization coil was placed in the selected intrahepatic PV successfully in six of seven animals, and Histoacryl injection was successful in five of them. In one case, histoacryl injection was failed due to needle deflection and early clogging. After coil insertion and histoacryl injection, disappearance of blood flow in the treated intrahepatic PV was confirmed by color Doppler. There was no adverse event in six animals during 1-week observation period. Necropsy revealed no evidence of damage to the treated intrahepatic PV and intra-abdominal organs. Conclusions: EUS-guided intrahepatic PVE can be both technically feasible and safe in a live porcine model. Further animal studies are needed to demonstrate the efficacy and long-term safety of this challenging intervention.


[PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed497    
    Printed6    
    Emailed0    
    PDF Downloaded31    
    Comments [Add]    

Recommend this journal