• Users Online:610
  • Home
  • Print this page
  • Email this page
Home About us Editorial board Search Ahead of print Current issue Archives Submit article Instructions Subscribe Contacts Login 

 Table of Contents  
IMAGES AND VIDEOS
Year : 2019  |  Volume : 8  |  Issue : 4  |  Page : 279-280

Antegrade stent deployment using a novel, covered metal stent through EUS-guided hepaticogastrostomy (with video)


2nd Department of Internal Medicine, Osaka Medical College, Osaka, Japan

Date of Submission19-Nov-2019
Date of Acceptance04-Jan-2019
Date of Web Publication15-Mar-2019

Correspondence Address:
Dr. Takeshi Ogura
2nd Department of Internal Medicine, Osaka Medical College, 2-7 Daigakuchou, Takatsukishi, Osaka 569-8686
Japan
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/eus.eus_5_19

Rights and Permissions

How to cite this article:
Ogura T, Nishioka N, Higuchi K. Antegrade stent deployment using a novel, covered metal stent through EUS-guided hepaticogastrostomy (with video). Endosc Ultrasound 2019;8:279-80

How to cite this URL:
Ogura T, Nishioka N, Higuchi K. Antegrade stent deployment using a novel, covered metal stent through EUS-guided hepaticogastrostomy (with video). Endosc Ultrasound [serial online] 2019 [cited 2019 Aug 19];8:279-80. Available from: http://www.eusjournal.com/text.asp?2019/8/4/279/254318



Antegrade stent deployment combined with EUS-guided hepaticogastrostomy (HGS) reportedly produces longer stent patency and prevents adverse events following biliary stent placement.[1],[2] In this procedure, uncovered metal stents are usually used as the antegrade stent to prevent stent dislocation. Recently, a novel, covered, self-expandable metal stent (FCSEMS) has become available in Japan (HIRZO STENT, BCM Co., Ltd, Gyeonggi-do, South Korea) [Figure 1]. This stent delivery system is available in an 8 Fr size and has a tapered tip. The diameter of the flanges is 14 mm and that of the body is 10 mm. The large flanges of this stent, compared with conventional FCSEMS, prevent stent migration and dislocation. We, herein, report the technique for performing EUS-HGS combined with antegrade stent deployment using this novel FCSEMS.
Figure 1: A novel, self-expandable, fully covered metal stent (HIRZO STENT, BCM Co., Ltd, Gyeonggi-do, South Korea)

Click here to view


The intrahepatic bile duct was punctured using a 19-gauge needle (Sono Tip Pro Control 19G; Medi-Globe GmbH, Rosenheim, Germany). Then, contrast medium was injected. A 0.025-inch guidewire (VisiGlide; Olympus Medical Systems, Tokyo, Japan) was inserted into the biliary tract. Then, an ERCP catheter (MTW Endoskopie, Düsseldorf, Germany) was inserted, and the contrast medium was injected again to evaluate the stricture site. The guidewire was advanced into the intestine across the stricture site [Figure 2]. Next, the stent delivery system of the novel FCSEMS was inserted [Figure 3], and stent deployment was carefully performed from the intestine to the upper common bile duct (10 mm × 6 cm) [Figure 4]. Finally, EUS-HGS was successfully performed using a plastic stent (Gadelius Medical Co, Ltd, Tokyo, Japan) without any adverse events [Figure 5] and Video 1]. No stent dysfunction was seen until the patient's death 4 months later. This stent may have clinical impact in stent deployment under both ERCP and EUS guidance, although additional cases are needed for its complete clinical evaluation.
Figure 2: Lower bile duct obstruction is seen under EUS-guided cholangiography imaging

Click here to view
Figure 3: The stent delivery system is inserted into the bile duct across the stricture site

Click here to view
Figure 4: Antegrade stent deployment is successfully performed

Click here to view
Figure 5: EUS-guided hepaticogastrostomy is performed using plastic stent

Click here to view





Declaration of patient consent

The authors certify that they have obtained all appropriate patient consent forms. In the form the patient has given his consent for his images and other clinical information to be reported in the journal. The patient understand that his name and initial will not be published and due efforts will be made to conceal his identity, but anonymity cannot be guaranteed.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.



 
  References Top

1.
Ogura T, Masuda D, Imoto A, et al. EUS-guided hepaticogastrostomy combined with fine-gauge antegrade stenting: A pilot study. Endoscopy 2014;46:416-21.  Back to cited text no. 1
    
2.
Ogura T, Kitano M, Takenaka M, et al. Multicenter prospective evaluation study of endoscopic ultrasound-guided hepaticogastrostomy combined with antegrade stenting (with video). Dig Endosc 2018;30:252-9.  Back to cited text no. 2
    


    Figures

  [Figure 1], [Figure 2], [Figure 3], [Figure 4], [Figure 5]



 

Top
 
 
  Search
 
Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
Access Statistics
Email Alert *
Add to My List *
* Registration required (free)

 
  In this article
   References
   Article Figures

 Article Access Statistics
    Viewed397    
    Printed13    
    Emailed0    
    PDF Downloaded18    
    Comments [Add]    

Recommend this journal


[TAG2]
[TAG3]
[TAG4]