• Users Online:744
  • Home
  • Print this page
  • Email this page
Home About us Editorial board Search Ahead of print Current issue Archives Submit article Instructions Subscribe Contacts Login 
ORIGINAL ARTICLE
Year : 2020  |  Volume : 9  |  Issue : 3  |  Page : 187-192

Diagnostic efficacy of white core cutoff lengths obtained by EUS-guided fine-needle biopsy using a novel 22G franseen biopsy needle and sample isolation processing by stereomicroscopy for subepithelial lesions


Department of Gastroenterology, Kitasato University School of Medicine, Sagamihara, Kanagawa, Japan

Correspondence Address:
Dr. Kosuke Okuwaki
Department of Gastroenterology, Kitasato University School of Medicine, 1-15-1 Kitasato, Minami, Sagamihara, Kanagawa, 252-0374
Japan
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/eus.eus_18_20

Rights and Permissions

Objectives: The aim of this study is to estimate the cutoff length for stereomicroscopically visible white core (SVWC) required for the pathological diagnosis of subepithelial lesions (SELs) from samples obtained using a novel 22-G Franseen biopsy needle and determine the sensitivity using the SVWC cutoff length. Patients and Methods: Thirty patients with SELs requiring pathological diagnoses were included. EUS-guided fine-needle biopsies (EUS-FNBs) were performed using a novel 22G Franseen biopsy needle. SVWC cutoff lengths were measured using sample isolation processing by stereomicroscopy (SIPS). The utility of the calculated SVWC cutoff lengths was measured. Results: The procedural success and SVWC sampling rates were both 100%. The median SVWC length was 14.5 mm. Pathological examinations identified 16 patients with gastrointestinal stromal tumors, 7 with schwannomas, 6 with leiomyomas, and 1 with an ectopic pancreas. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy for diagnosing malignancy using EUS-FNB were all 100%. The final diagnostic accuracy was 100%. Regarding the final diagnosis, based on the receiver operating characteristic curves calculated using the SVWC length, the area under the curve was 0.958 (95% confidence interval: 0.897–1.020, P < 0.001) and the cutoff length was 4 mm. The sensitivity of the new SVWC cutoff length was 98.7%. Conclusions: Diagnostic results of EUS-FNBs using a novel 22-G Franseen biopsy needle were significantly better with SVWC cutoff lengths ≥4 mm. Performing the SIPS procedure with a cutoff value of 4 mm as an index may be especially useful for successful pathological diagnosis of SELs at institutions where rapid on-site evaluation cannot be performed.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed140    
    Printed5    
    Emailed0    
    PDF Downloaded41    
    Comments [Add]    

Recommend this journal