• Users Online:28
  • Home
  • Print this page
  • Email this page
Home About us Editorial board Search Ahead of print Current issue Archives Submit article Instructions Subscribe Contacts Login 
ORIGINAL ARTICLE
Year : 2020  |  Volume : 9  |  Issue : 4  |  Page : 232-237

Validation of a novel swine model for training in EUS-FNA (with videos)


1 Department of Gastroenterology, Changhai Hospital, Navy Medical University, Shanghai, China
2 Department of Gastroenterology, Shenzhen People's Hospital, Guangdong Province, China
3 Medical College of Nantong University, Nantong, Jiangsu Province, China

Correspondence Address:
Dr. Kaixuan Wang
Department of Gastroenterology, Changhai Hospital, Navy Medical University, 168 Changhai Road, Shanghai 200433
China
Dr. Zhendong Jin
Department of Gastroenterology, Changhai Hospital, Navy Medical University, 168 Changhai Road, Shanghai 200433
China
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/eus.eus_13_20

Rights and Permissions

Background and Objectives: EUS-FNA is applied widely in clinical practice, but there remains a lack of authentic training models. The present study aimed to develop a novel swine training model and to perform a preliminary assessment of its feasibility and efficacy. Materials and Methods: To create an internal lesion-like target, empty shells of iodine-125 seeds were implanted into the caudate lobe of the liver in Bama minipigs. A training program involving 10 trainees was subsequently carried out, in which a total of 60 needlings were performed, composed of 6 for each trainee obtained during two training steps. Comparisons of procedure-related variables were conducted between the two. Trainees completed a questionnaire to assess their basic endoscopic experiences and reasonability of the model. Results: A target region of 2.0 cm × 2.0 cm in diameter was successfully established on the caudate lobe in all implanted pigs. In the training program, the average procedure time decreased from the first to the second step and the average time for the total 30 needlings' obtainment was significantly shorter for the second training step (23.8 ± 4.5 min vs. 40.9 ± 9.0 min, P < 0.001). For the second step, there was also a significant improvement in total success rate (86.7% vs. 56.7%, P = 0.020) and accuracy rate (76.7% vs. 43.3%, P = 0.017). All trainees scored the effectiveness of the model highly and all reported improved confidence after the training. Conclusion: This novel swine training model could authentically mimic clinical EUS-FNA, providing an effective in vivo practice tool for novices before clinical practice.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed512    
    Printed29    
    Emailed0    
    PDF Downloaded72    
    Comments [Add]    

Recommend this journal