• Users Online:94
  • Home
  • Print this page
  • Email this page
Home About us Editorial board Search Ahead of print Current issue Archives Submit article Instructions Subscribe Contacts Login 

 Table of Contents  
IMAGES AND VIDEOS
Year : 2020  |  Volume : 9  |  Issue : 4  |  Page : 267-269

One-step stent deployment of EUS-guided hepaticogastrostomy using a novel covered metal stent with a fine-gauge stent delivery system (with video)


2nd Department of Internal Medicine, Osaka Medical College, Osaka, Japan

Date of Submission31-Mar-2020
Date of Acceptance19-May-2020
Date of Web Publication20-Jul-2020

Correspondence Address:
Dr. Takeshi Ogura
2nd Department of Internal Medicine, Osaka Medical College, 2-7 Daigakuchou, Takatsukishi, Osaka 569-8686
Japan
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/eus.eus_38_20

Rights and Permissions

How to cite this article:
Ogura T, Yamada M, Nishioka N, Yamada T, Higuchi K. One-step stent deployment of EUS-guided hepaticogastrostomy using a novel covered metal stent with a fine-gauge stent delivery system (with video). Endosc Ultrasound 2020;9:267-9

How to cite this URL:
Ogura T, Yamada M, Nishioka N, Yamada T, Higuchi K. One-step stent deployment of EUS-guided hepaticogastrostomy using a novel covered metal stent with a fine-gauge stent delivery system (with video). Endosc Ultrasound [serial online] 2020 [cited 2020 Sep 24];9:267-9. Available from: http://www.eusjournal.com/text.asp?2020/9/4/267/290104



EUS-guided hepaticogastrostomy (EUS-HGS) is indicated for patients with surgically altered anatomy or an inaccessible papilla.[1],[2] The rate of adverse events is also not infrequent. Various kinds of adverse events have been reported, such as bleeding, bile peritonitis, or stent migration.[3],[4] During EUS-HGS, bile leakage into the abdominal cavity from the bile duct might occur after fistula dilation. If this step could be omitted, procedure time might be shortened. In addition, risk of bleeding due to dilation devices might also be reduced. Recently, a novel fully covered self-expandable metal stent with a fine-gauge stent delivery system (8 mm × 12 cm, HANAROSTENT® Biliary Full Cover Benefit™; M.I. Tech, Seoul, Korea) has become available in Japan [Figure 1]. This stent delivery system is only 5.9 Fr. In addition, the tip of this stent is extremely tapered and stiff. Herein, we describe a one-step stent deployment technique for EUS-HGS using this novel stent.
Figure 1: A novel fully covered self-expandable metal stent with a fine-gauge stent delivery system (8 mm × 12 cm, HANAROSTENT® Biliary Full Cover Benefit™; Boston Scientific Japan, Tokyo, Japan)

Click here to view


A 79-year-old female underwent gastrojejunostomy due to malignant duodenal obstruction caused by cancer of the pancreatic head. After this procedure, although she underwent chemotherapy, obstructive jaundice developed as a complication. EUS-HGS was therefore attempted. Because duodenal obstruction was complicated, antegrade stenting was not attempted to prevent reflux cholangitis. The intrahepatic bile duct was punctured using a 19-G needle. After aspirating bile juice, the contrast medium was injected [Figure 2]. Because stent deployment was performed in a single step, contrast medium injection was performed until an image of the left hepatic bile duct was obtained [Figure 3]. After the 0.025-inch guidewire was inserted into the common bile duct [Figure 4], insertion of the stent delivery system was attempted without any dilation. The stent delivery system was successfully inserted into the intrahepatic bile duct and was successfully deployed from the intrahepatic bile duct to the stomach without any adverse events [Figure 5]. During stent deployment, to prevent focal cholangitis, we carefully performed stent deployment from the confluence to the stomach as shown in Video 1. Until the patient's death (2 months later), no adverse events were seen.
Figure 2: The Intrahepatic Bile Duct Is Punctured Using 19G Needle, And The Contrast Medium Is Injected

Click here to view
Figure 3: The Contrast Medium Injection Is Performed Until Obtaining Left Intrahepatic Bile Duct

Click here to view
Figure 4: The Guidewire Is Inserted Into The Common Bile Duct

Click here to view
Figure 5: Stent Deployment Is Successfully Performed

Click here to view


In our technique, 0.025-inch guidewire was used. Compared with 0.035-inch guidewire, 0.025-inch guidewire is soft. However, benefit of 0.025-inch guidewire might be that guidewire manipulation is easily attempted compared with 0.035-inch guidewire because the resistance between guidewire and fine-needle aspiration needle is smaller in 0.025-inch guidewire. During EUS-HGS, guidewire manipulation is one of the limiting steps, as previously described.[5] In addition, recent 0.025-inch guidewire is relatively stiff. Therefore, we usually performed EUS-HGS using 0.025-inch guidewire. In view of fistula dilation, 0.035-inch guidewire might be helpful to obtain easy dilation. However, this novel stent is indicated with 0.025-inch guidewire. This might be one of the disadvantages of this novel stent.



In conclusion, our technique might reduce the rate of adverse events during EUS-HGS, although a prospective randomized trial is needed to confirm these findings.

Declaration of patient consent

The authors certify that they have obtained all appropriate patient consent forms. In the form the patient has given her consent for her images and other clinical information to be reported in the journal. The patient understands that her names and initials will not be published and due efforts will be made to conceal her identity, but anonymity cannot be guaranteed.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.



 
  References Top

1.
Giovannini M. EUS-guided hepaticogastrostomy. Endosc Ultrasound 2019;28:S44-9.  Back to cited text no. 1
    
2.
Paik WH, Park DH. Outcomes and limitations: EUS-guided hepaticogastrostomy. Endosc Ultrasound 2019;8:S44-S49.  Back to cited text no. 2
    
3.
Ogura T, Higuchi K. Technical tips for endoscopic ultrasound-guided hepaticogastrostomy. World J Gastroenterol 2016;22:3945-51.  Back to cited text no. 3
    
4.
Park DH, Jang JW, Lee SS, et al. EUS-guided biliary drainage with transluminal stenting after failed ERCP: Predictors of adverse events and long-term results. Gastrointest Endosc 2011;74:1276-84.  Back to cited text no. 4
    
5.
Vila JJ, Pérez-Miranda M, Vazquez-Sequeiros E, et al. Initial experience with EUS-guided cholangiopancreatography for biliary and pancreatic duct drainage: A Spanish national survey. Gastrointest Endosc 2012;76:1133-41.  Back to cited text no. 5
    


    Figures

  [Figure 1], [Figure 2], [Figure 3], [Figure 4], [Figure 5]



 

Top
 
 
  Search
 
Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
Access Statistics
Email Alert *
Add to My List *
* Registration required (free)

 
  In this article
   References
   Article Figures

 Article Access Statistics
    Viewed299    
    Printed9    
    Emailed0    
    PDF Downloaded52    
    Comments [Add]    

Recommend this journal


[TAG2]
[TAG3]
[TAG4]