Endoscopic Ultrasound

ORIGINAL ARTICLE
Year
: 2018  |  Volume : 7  |  Issue : 6  |  Page : 376--382

Safety and efficacy of ultra-tapered mechanical dilator for EUS-guided hepaticogastrostomy and pancreatic duct drainage compared with electrocautery dilator (with video)


Mitsuyoshi Honjo1, Takao Itoi1, Takayoshi Tsuchiya1, Reina Tanaka1, Ryosuke Tonozuka1, Shuntaro Mukai1, Atsushi Sofuni1, Yuichi Nagakawa2, Hidenori Iwasaki3, Takanori Kanai3 
1 Department of Gastroenterology and Hepatology, Tokyo Medical University, Tokyo, Japan
2 Department of Gastrointestinal and Pediatric Surgery, Tokyo Medical University, Tokyo, Japan
3 Department of Internal Medicine, Division of Gastroenterology and Hepatology, Keio University, Tokyo, Japan

Correspondence Address:
Dr. Takao Itoi
Department of Gastroenterology and Hepatology, Tokyo Medical University, 6-7-1 Nishishinjuku, Shinjuku-Ku, Tokyo 160-0023
Japan

Background and Objectives: Successful tract dilation is one of the most important steps to accomplish EUS-guided drainage. Although mechanical dilation is safer than electrocautery dilation, no dedicated mechanical dilator (MD) is currently available. Thus, we developed a new ultra-tapered MD for EUS-guided drainage. This study aimed to evaluate the safety and usefulness of this novel MD. Patients and Methods: Consecutive patients who underwent EUS-guided hepaticogastrostomy (EUS-HGS) or EUS-guided pancreatic duct drainage (EUS-PD) at two centers were included in the study. Dilation of the needle tract was initially performed with a diathermic sheath or the ultra-tapered MD. Technical success and adverse events were assessed. Results: Sixty-four patients (mean age = 68.9 ± 13.8 years, 35 men) underwent EUS-HGS (49 patients) and EUS-PD (15 patients). Thirty-three patients were included in the cautery dilator (CD) group and 31 in the ultra-tapered MD group. Initial dilation of the puncture site was achieved in 95.3% (61/64): 97% (32/33) of the patients in the CD group and 93.3% (29/31) of the patients in the MD group (P < 0.05). Adverse events were observed in 14 patients: abdominal pain in 8 patients and bleeding in 6 patients at the puncture site. All bleedings occurred in the CD group and there was no patient in whom bleeding occurred after EUS intervention in the MD group (P = 0.04). Conclusion: The novel ultra-tapered MD designed for interventional EUS appears to be safe and useful as it reduced postprocedure bleeding with a high technical success rate compared with the conventional electrocautery dilator.


How to cite this article:
Honjo M, Itoi T, Tsuchiya T, Tanaka R, Tonozuka R, Mukai S, Sofuni A, Nagakawa Y, Iwasaki H, Kanai T. Safety and efficacy of ultra-tapered mechanical dilator for EUS-guided hepaticogastrostomy and pancreatic duct drainage compared with electrocautery dilator (with video).Endosc Ultrasound 2018;7:376-382


How to cite this URL:
Honjo M, Itoi T, Tsuchiya T, Tanaka R, Tonozuka R, Mukai S, Sofuni A, Nagakawa Y, Iwasaki H, Kanai T. Safety and efficacy of ultra-tapered mechanical dilator for EUS-guided hepaticogastrostomy and pancreatic duct drainage compared with electrocautery dilator (with video). Endosc Ultrasound [serial online] 2018 [cited 2019 Jun 18 ];7:376-382
Available from: http://www.eusjournal.com/article.asp?issn=2303-9027;year=2018;volume=7;issue=6;spage=376;epage=382;aulast=Honjo;type=0